Abbott Diagnostics
10-Panel iCup® Rapid Drug Test by Abbott, 25/Box | I-DOA-1157-051
- SKU:
- I-DOA-1107-051
Bulk discount rates
Below are the available bulk discount rates for each individual item when you purchase a certain amount
| Quantity | Per Item |
| 1 - 3 | $156.50 |
| 4 - 7 | $151.81 |
| 8+ | $147.11 |
Description
10-Panel iCup Rapid Drug Test Kit (Adulterant Versions Available) by Abbott Diagnostics
The iCup Drug Screen Test Cup is the industry leader for accuracy and simplicity. The iCup self-contained one-step drug test results are visible within minutes. A positive result is indicated with one line and a negative result with two. An additional bonus with the iCup is that you may photocopy the results with the flat front, allowing you to maintain a visual record of the test. Built-in Adulteration versions are available. 10-Panel iCup® Rapid Drug Test by Abbott CLIA Waived is an all-in-one screening device designed for professional use in workplace and clinical environments.
The iCup offers a completely closed system for total urine specimen integrity and easy collection. The clear construction gives optimum observation of the urine specimen. The iCup drug screen kit is a single unit with no dipping or pouring. Test results develop quickly in the sealed unit. The system remains closed until disposal of the device. The iCup drug screen is a zero-exposure, leak-proof, and tamper-proof design. The iCup cup can be ordered with combinations of 3 to 13 panels.
What's Included?
iCup comes with a kit, cup, security seal, and drug screen result form. The iCup drug screen result form shows a diagram of the iCup and gives an example of positive results, negative results & invalid results. The form provides the names of each drug and their abbreviations making your job easier! Not to mention a product insert, a step-by-step instruction display for your staff. The iCup drug screen includes a temperature strip located on the back of the cup. This helps to ensure specimen integrity. The I-Cup drug screen also includes a quality control device built into the test itself, and a red line in the control region (C) is considered an internal procedural control. It confirms sufficient specimen volume, adequate membrane wicking, and correct procedural technique.
Features & Benefits
- Sold by the Box of 25 Test Kits
- Photocopy Template and Two-part result form available upon request
- Security Seal
- FDA 510(k) Cleared
- Temperature Strip
- Room temperature storage
- SAMHSA Lab GC/MS Confirmation optional - Call for information
- Built-in validity test
- Immediate Results
- Detects from 3 to 13 drugs
- Simple procedure
- Fast results
- Adheres to SAMSHA Cutoff Levels
- Cut-off levels of drug testing set according to SAMHSA
- Shelf-life 24 months from date of manufacture
- 99% Accurate test results in 5 minutes
|
i-Cup Reference Materials (click to view & print) |
|
| iCup 10 Panel Configurations | ||
| Item Number | Drugs Tested (Select Item Number Above) | Adulterants Tested |
| I-DOA-1107-051 | COC, THC, OPI, AMP, mAMP, BZO, BAR, OXY, MDMA, PPX | None |
| I-DUD-1107-012 | COC, THC, OPI, AMP, mAMP, PCP, BZO, BAR, MTD, TCA | OX - Oxidants SG - Specific Gravity PH - pH Level NI - Nitrates GL - Glutaraldehyde CR - Creatinine |
| I-DUE-1107-141 | COC, THC, OPI, AMP, mAMP, BZO, BAR, OXY, MDMA, PPX | OX - Oxidants CR - Creatinine PH - pH Level |
| I-DUE-1107-291 | AMP, BAR, BZO, COC, mAMP, MDMA, MOR, OXY, PCP, THC | OX - Oxidants SG - Specific Gravity PH - pH Level |
| iCup Urine Drug Panel Detection Chart | ||||
| Drug Name / Abbreviation | Calibrator | Cutoff | Minimum Detection Time* | Maximum Detection Time* |
| Amphetamine (AMP) | d-Amphetamine | 1000 ng/ml | 2-7 hours | 2-4 days |
| Barbiturates (BAR) | Secobarbital | 300 ng/ml | 2-4 hours | 1-3 weeks |
| Benzodiazepines (BZO) | Oxazepam | 300 ng/ml | 2-7 hours | 1-4 days |
| Buprenorphine (BUP) | Buprenorphine | 10 ng/ml | 2-7 hours | 2-3 days |
| Cocaine (COC) | Benzoylecgonine | 300 ng/ml | 1-4 hours | 2-4 days |
| Ecstasy (MDMA) | d,l Methylenedioxymethamphetamine | 500 ng/ml | 2-7 hours | 2-4 days |
| Marijuana (THC) | 11-nor-Δ9-THC-9 COOH | 50 ng/ml | 2 hours | up to 40 days |
| Methadone (MTD) | Methadone | 300 ng/ml | 3-8 hours | 1-3 days |
| Methamphetamine (mAMP) | d-Methamphetamine | 1000 ng/ml | 2-7 hours | 2-4 days |
| Morphine (MOP / OPI-300) | Morphine | 300 ng/ml | 2 hours | 2-3 days |
| Opiates (OPI) | Morphine | 2000 ng/ml | 2 hours | 2-3 days |
| Oxycodone (OXY) | Oxycodone | 100 ng/ml | 1-3 hours | 1-2 days |
| Phencyclidine (PCP) | Phencyclidine | 25 ng/ml | 4-6 hours | 7-14 days |
| Tricyclic Antidepressants (TCA) | Nortriptyline | 1000 ng/ml | 8-12 hours | 2-7 days |
| Propoxyphene (PPX) | Propoxyphene | 300 ng/ml | 2-7 hours | 2-3 days |
| * Detection times are not guaranteed. This assay provides only a preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas Chromatography/Mass Spectrometry (GC/MS) is the preferred confirmatory method. Clinical consideration and professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are indicated. | ||||