Description
9 Panel iCup® Drug Tests: I-DOA-197-041 and I-DUD-197-014
Sold by the Box of 25 Tests
The iCup® Drug Screen Test Cup is the industry leader for accuracy and simplicity. The iCup self-contained one-step drug test results are visible within minutes. A positive result is indicated with one line and a negative result with two. An additional bonus with the iCup is that you may photocopy the results with the flat front, allowing you to maintain a visual record of the test. Built-in Adulteration versions are available. 9 Panel iCup® Drug Test with Adulterants by Abbott is a professional screening tool that ensures sample integrity and provides accurate results in minutes.
The iCup offers a completely closed system for total urine specimen integrity and easy collection. The clear construction gives optimum observation of the urine specimen. The iCup drug screen kit is a single unit with no dipping or pouring. Test results develop quickly in the sealed unit. The system remains closed until disposal of the device. The iCup drug screen is zero-exposure, leak-proof, and tamper-proof design. The iCup cup can be ordered with combinations from 3 to 13 panels.
What's Included?
iCup comes with a kit, cup, security seal, and drug screen result form. The iCup drug screen result form shows a diagram of the iCup and gives an example of positive results, negative results & invalid results. The form provides the names of each drug and their abbreviations, making your job easier! Not to mention a product insert, a step-by-step instruction display for your staff. The iCup drug screen includes a temperature strip located on the back of the cup. This helps to ensure specimen integrity. The I-Cup drug screen also includes a quality control device built into the test itself, and a red line in the control region (C) is considered an internal procedural control. It confirms sufficient specimen volume, adequate membrane wicking, and correct procedural technique.
Features & Benefits
- Sold by the Box of 25 Test Kits
- Photocopy Template and Two-part result form available upon request
- Security Seal
- FDA 510(k) Cleared
- Temperature Strip
- Room temperature storage
- SAMHSA Lab GC/MS Confirmation optional - Call for information
- Built-in validity test
- Immediate Results
- Detects from 3 to 13 drugs
- Simple procedure
- Fast results
- Adheres to SAMSHA Cutoff Levels
- Cut-off levels of drug testing set according SAMHSA
- Shelf-life 24 months from date of manufacture
- 99% Accurate test results in 5 minutes
| i-Cup® Reference Materials | |
| iCup® 9 Panel Configurations (choose panel above) | |||
| Item Number | Drug Tests Included | Adulterants Included | Regulatory Approvals |
| I-DOA-197-041 | COC, THC, OPI, AMP, mAMP, PCP, BZO, BAR, PPX | None | Moderately Complex FDA 510(k) |
| I-DUD-197-014 | COC, THC, OPI, AMP, mAMP, PCP, BZO, BAR, MTD | OX - Oxidants CR - Creatinine PH - pH Level SG - Specific Gravity NI - Nitrates GL - Glutaraldehyde |
Moderately Complex FDA 510(k) |
| * Meets SAMHSA cutoff levels. ** Lower than SAMHSA-recommended guidelines. This assay provides only a preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas Chromatography/Mass Spectrometry (GC/MS) is the preferred confirmatory method. Clinical consideration and professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are indicated. |
||
| Drug Name | Target Drug | Cutoff Level |
|---|---|---|
| Amphetamine (AMP 1000) | D-Amphetamine | 1,000 ng/mL |
| Amphetamine (AMP 300) | D-Amphetamine | **300 ng/mL |
| Barbiturates (BAR) | Secobarbital | 300 ng/mL |
| Benzodiazepines (BZO) | Oxazepam | 300 ng/mL |
| Cocaine (COC 300) | Benzoylecgonine | 300 ng/mL |
| Cocaine (COC 150) | Benzoylecgonine | *150 ng/mL |
| Marijuana (THC) | 11-nor-Δ9-THC-9 COOH | *50 ng/mL |
| Methadone (MTD) | Methadone | 300 ng/mL |
| Methamphetamine (M-AMP 1000) | D-Methamphetamine | 1000 ng/mL |
| Methamphetamine (M-AMP 500) | D-Methamphetamine | *500 ng/mL |
| Methylenedioxymeth-amphetamine (MDMA) | D,L Methylenedioxy-methamphetamine | 500 ng/mL |
| Opiates (OPI2 2000) | Morphine | *2000 ng/mL |
| Opiates (OPI 300) | Morphine | **300 ng/mL |
| Oxycodone (OXY) | Oxycodone | 100 ng/mL |
| Phencyclidine (PCP) | Phencyclidine | *25 ng/mL |