  • Abbott Toxicology -Panel Integrated EZ Split Key Cup - Open
  • Abbott Toxicology -Panel Integrated EZ Split Key Cup
Now: $70.00
Was: $101.25

PLEASE CALL 800-915-7017 FOR SPECIAL PRICING ON LARGER ORDERS

 

Description

5-Panel Integrated E-Z Split Specimen Key Cup Drug Test, 25/Box | DUD-157-012-019

Short-dated Stock - Expiration 6/17/26 - Price Reflects Discount

The 5-Panel Integrated EZ Split Key Cup is administrator-controlled. The absorbent test strips are separated from the urine sample in the “split-specimen” container. The test strips come into contact with the urine specimen only after the drug test administrator pushes in the "key" at the base of the cup. Abbott 5 Panel EZ Split Key Cup Drug Test CLIA Waived is ideal for workplace drug testing, providing fast results while maintaining sample integrity for confirmation.

The Integrated EZ Split Key Cup is FDA-approved and widely used for both clinical and workplace drug testing. These drug test cups will screen for 3-12 different drugs of abuse. 

Features

  • 25 drug test kits per box
  • 12-18 month expiration date on all urine drug test cups (guaranteed)
  • FDA-approved
  • CLIA-Waived
  • Fast results in 5 minutes
  • Free FedEx Ground Shipping with $150 Order

EZ Split Key Cup 5-Panel Tests Are Accurate and Easy to Use

  1. Remove the E-Z Cup urine drug test from the foil pouch
  2. Remove the "key" from the center of the cup cap
  3. Donor provides urine specimen (note: minimum fill line)
  4. Secure the cap tightly by pressing down on the lid until you hear the click
  5. Insert the key at the base of the cup and depress completely to initiate the test. Start the timer
  6. Read the temperature strip affixed to the test cup between 2 and 4 minutes. Temperature readings outside of the 90-100° range may indicate dilution or tampering
  7. Peel the label off the multi-drug test card to view results, read and interpret the E-Z Cup drug test results at 5 minutes

Reading EZ Split Key Cup Drug Test Results
Note: All faint lines, including barely visible ones, should be interpreted as "negative"

drug-test-results-reading-panel-interpretation.png

Integrated EZ Split Key Cup Instructions & Documentation
PDF Logo E-Z Split Key Cup Package Insert PDF Logo Alere i-Cup Drug Test Instructions
PDF Logo Alere i-Cup Drug Test Procedure Card PDF Logo EZ Integrated Split Key Cup Cross Reactivity Chart by Drug
5 Panel EZ Split Specimen Key Cup
Product Code Test Panels Built-In Adulteration Panels
DUD-157-012-019 COC, THC, OPI, AMP, mAMP SG, PH, NI, GL, CR
View AllClose

Additional Information

Per Each:
25